• Menu
  • Product
  • Email
  • PDF
  • Order now
  • MCF83xx - Open Loop to Closed Loop Handoff Tuning

    • SLLA665 April   2025 MCF8315A , MCF8315C , MCF8315C-Q1 , MCF8315D , MCF8316A , MCF8316C-Q1 , MCF8316D , MCF8329A , MCF8329A-Q1

       

  • CONTENTS
  • SEARCH
  • MCF83xx - Open Loop to Closed Loop Handoff Tuning
  1.   1
  2.   Abstract
  3.   Trademarks
  4. 1Introduction
    1. 1.1 Open Loop and Handoff Stage
  5. 2EEPROM Configurations Affecting Open Loop to Closed Loop Handoff
  6. 3Open Loop to Closed Loop Handoff Tuning
    1. 3.1 Experimental Way to Tune Open Loop and Handoff Stage
      1. 3.1.1 Step-1: Initial Configuration
      2. 3.1.2 Step-2: Tuning of Parameters In Case Handoff is not Proper
        1. 3.1.2.1 Tuning of OL_ILIMIT
        2. 3.1.2.2 Tuning of Open Loop Acceleration Co-Efficient A1
        3. 3.1.2.3 Tuning of Handoff Thresholds
      3. 3.1.3 Step-3: Tuning of Handoff Configurations
  7. 4Optimum Handoff
    1. 4.1 Open Loop Time With the Recommended Settings
    2. 4.2 Open Loop Time by Following Optimum Handoff Steps
  8. 5Summary
  9. 6References
  10. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

Application Note

MCF83xx - Open Loop to Closed Loop Handoff Tuning

 

Texas Instruments

© Copyright 1995-2025 Texas Instruments Incorporated. All rights reserved.
Submit documentation feedback | IMPORTANT NOTICE | Trademarks | Privacy policy | Cookie policy | Terms of use | Terms of sale