  • CC2564C: BT (BR/EDR) SIG Errata 11838 - LMP Encryption Key Minimum Size Change

    • SWRA806 August   2019 CC2564C

       

  • CONTENTS
  • SEARCH
  • CC2564C: BT (BR/EDR) SIG Errata 11838 - LMP Encryption Key Minimum Size Change
  1.   1
  2. 1Summary
  3. 2Vulnerability
  4. 3Revision History
  5. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

PSIRT Notification

CC2564C: BT (BR/EDR) SIG Errata 11838 - LMP Encryption Key Minimum Size Change

1 Summary

As described in the Bluetooth Special Interest Group (SIG) announcement, errata 11838 proposes the following changes to be applied to the Core Specifications to incorporate the various encryption key size related updates:

  • The minimum encryption key size used for the LMP_encryption_key_size_req PDU shall be set to at least 7 octets.
  • All BR/EDR Controllers shall implement the Read Encryption Key Size command (0x1408).

2 Vulnerability

TI PSIRT ID

TI-PSIRT-2019-010018

Affected Products

TI has identified that there are no changes required for the Read Encryption Key Size command and the change in the minimum encryption key size requirement applies to the TI Bluetooth controllers with BR/EDR support:

  • TI Dual-Mode Bluetooth controllers: CC256x, CC256xB, CC2564C, WL12xx, and WL18xx devices.

Customers using these devices should reference information available from Bluetooth (SIG) to understand more about the nature of this change.

Fixed Products

The following software updates are available for TI devices implementing Bluetooth Erratum 11838:

  • CC2564C SP
  • CC256XB SP
  • WL18xx SP

The current and existing Bluetooth Core Specifications for Low Energy (LE) devices implementing LE Legacy Pairing and LE Secure Connections (LESC) already require a minimum encryption key length of 7 octets and are thus not applicable to Bluetooth Erratum 11838.

Note: For information on other TI devices with BR/EDR support that are not listed above, please contact ti_bt_errata@list.ti.com.

3 Revision History

DATE REVISION NOTES
August 2019 * Initial Release

 

Texas Instruments

© Copyright 1995-2025 Texas Instruments Incorporated. All rights reserved.
Submit documentation feedback | IMPORTANT NOTICE | Trademarks | Privacy policy | Cookie policy | Terms of use | Terms of sale