• Menu
  • Product
  • Email
  • PDF
  • Order now
  • BQ2461x Stand-Alone 1- to 6-Cell Synchronous Buck Battery Charger Controller

    • SLUS892D December   2009  – December 2019 BQ24610 , BQ24617

      PRODUCTION DATA.  

  • CONTENTS
  • SEARCH
  • BQ2461x Stand-Alone 1- to 6-Cell Synchronous Buck Battery Charger Controller
  1. 1 Features
  2. 2 Applications
  3. 3 Description
    1.     Device Images
      1.      Simplified Schematic
  4. 4 Revision History
  5. 5 Description (continued)
  6. 6 Device Comparison Table
  7. 7 Pin Configuration and Functions
    1.     Pin Functions
  8. 8 Specifications
    1. 8.1 Absolute Maximum Ratings
    2. 8.2 ESD Ratings
    3. 8.3 Recommended Operating Conditions
    4. 8.4 Thermal Information
    5. 8.5 Electrical Characteristics
    6. 8.6 Typical Characteristics
  9. 9 Detailed Description
    1. 9.1 Overview
    2. 9.2 Functional Block Diagram
    3. 9.3 Feature Description
      1. 9.3.1  Battery Voltage Regulation
      2. 9.3.2  Battery Current Regulation
      3. 9.3.3  Input Adapter Current Regulation
      4. 9.3.4  Precharge
      5. 9.3.5  Charge Termination, Recharge, and Safety Timer
      6. 9.3.6  Power Up
      7. 9.3.7  Enable and Disable Charging
      8. 9.3.8  System Power Selector
      9. 9.3.9  Automatic Internal Soft-Start Charger Current
      10. 9.3.10 Converter Operation
      11. 9.3.11 Synchronous and Nonsynchronous Operation
      12. 9.3.12 Cycle-by-Cycle Charge Undercurrent Protection
      13. 9.3.13 Input Overvoltage Protection (ACOV)
      14. 9.3.14 Input Undervoltage Lockout (UVLO)
      15. 9.3.15 Battery Overvoltage Protection
      16. 9.3.16 Cycle-by-Cycle Charge Overcurrent Protection
      17. 9.3.17 Thermal Shutdown Protection
      18. 9.3.18 Temperature Qualification
      19. 9.3.19 Timer Fault Recovery
      20. 9.3.20 PG Output
      21. 9.3.21 CE (Charge Enable)
      22. 9.3.22 Charge Status Outputs
      23. 9.3.23 Battery Detection
    4. 9.4 Device Functional Modes
  10. 10Application and Implementation
    1. 10.1 Application Information
    2. 10.2 Typical Applications
      1. 10.2.1 System with Power Path
        1. 10.2.1.1 Design Requirements
        2. 10.2.1.2 Detailed Design Procedure
          1. 10.2.1.2.1 Inductor Selection
          2. 10.2.1.2.2 Input Capacitor
          3. 10.2.1.2.3 Output Capacitor
          4. 10.2.1.2.4 Power MOSFETs Selection
          5. 10.2.1.2.5 Input Filter Design
          6. 10.2.1.2.6 Inductor, Capacitor, and Sense Resistor Selection Guidelines
        3. 10.2.1.3 Application Curves
      2. 10.2.2 Simplified System without Power Path or DPM
        1. 10.2.2.1 Design Requirements
        2. 10.2.2.2 Detailed Design Procedure
        3. 10.2.2.3 Application Curves
      3. 10.2.3 Lead-Acid Charging System
        1. 10.2.3.1 Design Requirements
        2. 10.2.3.2 Detailed Design Procedure
        3. 10.2.3.3 Application Curves
  11. 11Power Supply Recommendations
  12. 12Layout
    1. 12.1 Layout Guidelines
    2. 12.2 Layout Example
  13. 13Device and Documentation Support
    1. 13.1 Device Support
      1. 13.1.1 Third-Party Products Disclaimer
    2. 13.2 Related Links
    3. 13.3 Receiving Notification of Documentation Updates
    4. 13.4 Support Resources
    5. 13.5 Trademarks
    6. 13.6 Electrostatic Discharge Caution
    7. 13.7 Glossary
  14. 14Mechanical, Packaging, and Orderable Information
  15. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

DATA SHEET

BQ2461x Stand-Alone 1- to 6-Cell Synchronous Buck Battery Charger Controller

1 Features

  • 600-kHz NMOS-NMOS Synchronous buck converter
  • Stand-alone charger support for li-ion or li-polymer
  • 5-V to 28-V VCC Input operating range and supports 1- to 6-battery cells (BQ24610)
  • 5-V to 24-V VCC Input operating range and supports 1- to 5-battery cells (BQ24617)
  • Up to 10-A charge current and adapter current
  • High-accuracy voltage and current regulation
    • ±0.5% Charge voltage accuracy
    • ±3% Charge current accuracy
    • ±3% Adapter current accuracy
  • Integration
    • Automatic system power selection from adapter or battery
    • Non Power Path option for low total BOM cost
    • Internal loop compensation and soft start
    • Dynamic power management
  • Safety protection
    • Input overvoltage protection
    • Battery thermistor sense hot and cold charge suspend
    • Battery detection
    • Reverse protection input FET
    • Programmable safety timer
    • Charge overcurrent protection
    • Battery short protection
    • Battery overvoltage protection
    • Thermal shutdown
  • Status Outputs
    • Adapter present
    • Charger operation status
  • Charge enable pin
  • 6-V Gate drive for synchronous buck converter
  • Energy star low quiescent current Iq
    • < 15-µA Off-state battery discharge current
    • < 1.5-mA Off-state input quiescent current

2 Applications

  • Netbooks, mobile internet devices, and ultra-mobile PCs
  • Personal digital assistants (PDAs)
  • Handheld terminals
  • Industrial and medical equipment
  • Portable equipment

3 Description

The BQ2461x is a highly integrated Li-ion, Li-polymer or Lead-acid switched-mode battery charge controller. The device offers a constant-frequency synchronous switching PWM controller with high-accuracy charge current and voltage regulation, charge preconditioning, termination, adapter current regulation, and charge status monitoring.

Device Information(1)

PART NUMBER PACKAGE BODY SIZE (NOM)
BQ24610 VQFN (24) 4.00 mm × 4.00 mm
BQ24617