• Menu
  • Product
  • Email
  • PDF
  • Order now
  • TIOL112(x) Functional Safety FIT Rate, FMD and Pin FMA

    • SFFS380 February   2022 TIOL112 , TIOL1123 , TIOL1125

       

  • CONTENTS
  • SEARCH
  • TIOL112(x) Functional Safety FIT Rate, FMD and Pin FMA
  1.   Trademarks
  2. 1Overview
  3. 2Functional Safety Failure In Time (FIT) Rates
  4. 3Failure Mode Distribution (FMD)
  5. 4Pin Failure Mode Analysis (Pin FMA)
  6. 5Revision History
  7. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

FUNCTIONAL SAFETY FIT RATE, FMD AND PIN-FMA

TIOL112(x) Functional Safety FIT Rate, FMD and Pin FMA

Trademarks

All trademarks are the property of their respective owners.

1 Overview

This document contains information for TIOL112(x) family of devices (TIOL112, TIOL1123 and TIOL1125) to aid in a functional safety system design. Information provided are:

  • Functional Safety Failure In Time (FIT) rates of the semiconductor component estimated by the application of industry reliability standards
  • Component failure modes and their distribution (FMD) based on the primary function of the device
  • Pin failure mode analysis (Pin FMA)

Figure 1-1 and Figure 1-2 show the device functional block diagram for reference.

Figure 1-1 Functional Block Diagram (TIOL112)
Figure 1-2 Functional Block Diagram (TIOL1123, TIOL1125)

The devices were developed using a quality-managed development process, but was not developed in accordance with the IEC 61508 or ISO 26262 standards.

2 Functional Safety Failure In Time (FIT) Rates

This section provides Functional Safety Failure In Time (FIT) rates for TIOL112(x) family based on two different industry-wide used reliability standards:

  • Table 2-1 provides FIT rates for TIOL1123/TIOL1125 (with LDO) based on IEC TR 62380 / ISO 26262 part 11
  • Table 2-2 provides FIT rates for TIOL112 (without LDO) based on IEC TR 62380 / ISO 26262 part 11
  • Table 2-3 provides FIT rates based on the Siemens Norm SN 29500-2

Table 2-1 Component Failure Rates per IEC TR 62380 / ISO 26262 Part 11 (TIOL1123, TIOL1125)
FIT IEC TR 62380 / ISO 26262 FIT (Failures Per 109 Hours)

DRC-10 (VSON Package)

Total Component FIT Rate

9

Die FIT Rate

5

Package FIT Rate 4

The failure rate and mission profile information in Table 2-1 comes from the Reliability data handbook IEC TR 62380 / ISO 26262 part 11:

  • Mission Profile: Motor Control from Table 11
  • Power dissipation: 550 mW
  • Climate type: World-wide Table 8
  • Package factor lambda 3 Table 17b
  • Substrate Material: FR4
  • EOS FIT rate assumed: 0 FIT

Table 2-2 Component Failure Rates per IEC TR 62380 / ISO 26262 Part 11 (TIOL112)
FIT IEC TR 62380 / ISO 26262 FIT (Failures Per 109 Hours)

DRC-10 (VSON Package)

Total Component FIT Rate

7

Die FIT Rate

3

Package FIT Rate 4
The failure rate and mission profile information in Table 2-2 comes from the Reliability data handbook IEC TR 62380 / ISO 26262 part 11:
  • Mission Profile: Motor Control from Table 11
  • Power dissipation: 200 mW
  • Climate type: World-wide Table 8
  • Package factor lambda 3 Table 17b
  • Substrate Material: FR4
  • EOS FIT rate assumed: 0 FIT
Table 2-3 Component Failure Rates per Siemens Norm SN 29500-2
Table Category Reference FIT Rate Reference Virtual TJ
5 BICMOS, ASIC, Analog & Mixed ≤ 50 V Supply 25 FIT 55°C

The Reference FIT Rate and Reference Virtual TJ (junction temperature) in Table 2-3 come from the Siemens Norm SN 29500-2 tables 1 through 5. Failure rates under operating conditions are calculated from the reference failure rate and virtual junction temperature using conversion information in SN 29500-2 section 4.

 

Texas Instruments

© Copyright 1995-2025 Texas Instruments Incorporated. All rights reserved.
Submit documentation feedback | IMPORTANT NOTICE | Trademarks | Privacy policy | Cookie policy | Terms of use | Terms of sale