  • 3.6kW CCM-TCM Multimode Controlled Totem-Pole Bridgeless PFC Reference Design

    • TIDT439 March   2025

       

  • CONTENTS
  • SEARCH
  • 3.6kW CCM-TCM Multimode Controlled Totem-Pole Bridgeless PFC Reference Design
  1.   1
  2.   Description
  3.   Features
  4.   Applications
  5. 1Test Prerequisites
    1. 1.1 Key System Specifications
    2. 1.2 Required Equipment
    3. 1.3 Considerations
    4. 1.4 Test Setup
    5. 1.5 Power Up Procedure
  6. 2Testing and Results
    1. 2.1 Efficiency Graphs
    2. 2.2 Efficiency Data
    3. 2.3 Thermal Images
  7. 3Waveforms
    1. 3.1 Start-up Waveform
    2. 3.2 Input Current Waveform
    3. 3.3 Load Transients
    4. 3.4 AC Drop Test
    5. 3.5 THD and PF
    6. 3.6 E-Meter Performance
  8. IMPORTANT NOTICE
search No matches found.
  • Full reading width
    • Full reading width
    • Comfortable reading width
    • Expanded reading width
  • Card for each section
  • Card with all content

 

Test Report

3.6kW CCM-TCM Multimode Controlled Totem-Pole Bridgeless PFC Reference Design

 

Texas Instruments

© Copyright 1995-2025 Texas Instruments Incorporated. All rights reserved.