1 Overview

This document contains information for TMP102-Q1 (SOT563-6 package) to aid in a functional safety system design. Information provided are:

  • Functional Safety Failure In Time (FIT) rates of the semiconductor component estimated by the application of industry reliability standards
  • Component failure modes and their distribution (FMD) based on the primary function of the device

Figure 1-1 shows the device functional block diagram for reference.

GUID-E38220F8-4009-425B-9C2F-EB92314D02F8-low.gifFigure 1-1 Functional Block Diagram

TMP102-Q1 was developed using a quality-managed development process, but was not developed in accordance with the IEC 61508 or ISO 26262 standards.

 